Detailed Description
1. Co
ntrol system: It uses the Mitsubishi PLC which has large storage memory, quick signal relay, simple structure, high reliable, anti-interference capabilities and so on; Ensuring the safe and reliable operation of the escalator
2. Driving System: VVVF technology
3. Four kinds of running mode ba
sed on passenger flow rate: Normal Speed, Eco-Dual Speed, Intelligent travel, Bi-directio
nal Modes, With this function it helps the equipment to co
nserve energy thereby saving operatio
nal cost
1 | Emergency Stop Button | If pssed in a emergency, stops the moving escalator/ conveyor immediately. | Standard |
2 | Motor Speed Device | If the speed above normal speed, stops the moving escalator/ conveyor. |
3 | Motor Over Heat Device | Stops the moving escalator/ conveyor, if the motor is over heat |
4 | Driving Chain Safety Device | Stops the moving escalator/ conveyor, if the driving chain breaks or excessively looses. |
5 | Handrail Inlet Safety Device | Stops the moving escalator/ conveyor, if hand or object is pulled into the handrail inlet. |
6 | Step Sagging Device | Stops the moving escalator/ conveyor, if step are operating in abnormal manner. |
7 | Non Reversing Safety Device | Stops the moving escalator/ conveyor, if its direction of travel is reversed. |
8 | Maintenance Switch | Cuts off operating circuits when maintenance inspection or repair is performed. |
9 | Absent or mistaken epsilon phase device | Escalator/ conveyor can't operate, if Absent or mistaken epsilon phase device |
10 | Comb plate safety device | Stops the moving escalator/ conveyor, if objects are caught between comb plate and pallet treads. |
11 | Motor braking safety device | Help the motor brake properly |
12 | Skirt Guard Safety Device | Stops the moving escalator/ conveyor, if objects are caught between pallet skirts. |
13 | Handrail Speed Monitoring Device | Stops the moving escalator/ conveyor, if handrail speed is below normal due to handrail breakage or elongation. |
14 | Alarm bell | Ringing alarm bell, if escalator/ conveyor operate normally |
15 | Auto- lubricate device | Auto- lubricate to escalator/ conveyor |
16 | Pallet Demarcation | Yellow two demarcation lines provide a visual and physical warming of the pallet edges |
17 | Self-diagnose Device | Self-diagnose the whole system, if escalator/ conveyor run normally | Option |
18 | Skirting illumination | Lamps are provides at the both sides of skirt panel
|
****************************************************